SUTOP DOUBLE ® ELASTIC

Cement and Acryllic-Based Double Component Elastic Water Insulation Material



APPLICATION FIELD

Used in wet areas such as bathrooms, WCs, kitchens, balconies, etc. and for insulation of water tanks, pools and terraces.

Applied on surfaces such as concrete, plaster and screed.

+
REQUIREMENTS

  • No contraction cracks occur due to its elasticity.
  • It may be easily and rapidly applied.
  • May be applied on horizontal and vertical surfaces.
  • Has a superior adherence.
  • Applied against positive water pressure.


TECHNICAL VALUES

Water Vapour Permeability
Class I
Shear Tensile Adhesive Strength
With no traffic load / Flexible
Class of Reaction To Fire
E
Adhesive Strength, N/mm²
≥ 1
Capillary Water Absorption, (kg/m²·h⁰·⁵)
Max 0,1
Crack Bridging Ability, mm
> 0,75




APPLICATION

SURFACE PREPARATION

  • The surface of application shall be solid, clean, free of dust and level.
  • The surface shall always be free of materials such as form oil, paint, dust etc., and shall be fully cured.
  • Parts on the surface (iron, wood, etc.) shall be removed and these hole shall be filled with appropriate Entegre Repair Mortars.
  • You may advance to application after dampening the surface.

PREPARATION of the MORTAR

  • A proper amount of fluid component shall be put inside the mixing vessel (10 kg of fluid/25 kg of powder).
  • Whole bag is poured to the vessel, and stirred with hand mixer until the lumps are removed.
  • After resting for 5 minutes, the mortar shall be stirred again.
  • ENTEGRE CHAMFERING TAPE shall be applied to the connection points of the application surfaces using EPODOL®.
  • If you do not prefer chamfering tapes, bring the connection points to an oval form and reinforce them with nets.
  • Fluid mortar shall be applied with a brush or a roll.
  • Second coat shall be perpendicular to the first coat and shall be applied at least for 6 hours later.
  • Wait 3 days for application of final coat (ceramic, screed and cement-based plaster), and take care to prevent mechanical damage to the insulation material during coating.
  • If the application area is a water tank, wait at least 28 days for the curing of the product.

1
SUTOP DOUBLE ELASTIC Image 1

2
SUTOP DOUBLE ELASTIC Image 2

3
SUTOP DOUBLE ELASTIC Image 3

📊
CONSUMPTION

1.5-2.0 kg per m² for single coat

(Under proper surface and ambient conditions. It may differ as per surface specifications and application conditions.)

📦
PACKAGING

A Component: 25 kg polyethylene-reinforced kraft paper bags,
B Component: 10 kg plastic drums
(delivered in pallets or as sling-bags upon request.)

💾
STORING

1 Year Shelf Life*
* If stored in its original package without opening the package under dry, frost free conditions
(1 week after opening the package.
Liquid component freezes at temperatures below 0°C.)


RECOMMENDATION

  • No other materials than these two components (lime, cement, gypsum, etc.) shall be added.
  • We recommend you to stir the product continuously during application.
  • Mortar shall not be used again by mixing with water, fluid component or dry mortar if its application time has expired.
  • We recommend that the application shall be performed between +5°C and +35°C.
  • SUTOP DOUBLE® ELASTIC shall be protected against effects such as sunlight, wind, rain and frost, etc. within the first 24 hours after application.
  • Reaches its final strength within 14 days.
  • It shall not be applied on frozen surfaces.
  • Do not apply under direct sunlight.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the security data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.


CERTIFICATE OF CONFORMITY

TS EN 1504-2 / April 2008

It is suitable for contact with drinking water as per BS6920 standard.

(ODTU-Department of Chemical Engineering
Report No: 2016.03.04,039/02 Report Date: 17/03/2016)

Ministry of Public Works Pos. No: 04,477/1

TSE Logo

CE Logo

TCL Logo

×