SUTOP® PU-1B

Polyurethane-Based UV Resistant Single Component Elastic Water Insulation Material



APPLICATION FIELD

  • Used safely on terraces, ceilings, balconies and gutters,
  • On foundation and curtain walls, window boxes,
  • On the exterior façades of the buildings,
  • In wet areas under tiles,
  • For the UV strength of polyurethane foam applications,
  • And against water and corrosion on applications such as concrete, rock, eternit, wood and metal sheets, etc.

+
REQUIREMENTS

  • It has a single component and is ready to use.
  • It may be applied easily (With a roll or an airless sprayer).
  • It may be applied without any joints.
  • Resistant against collected water.
  • Offers high resistance against UV and frost.
  • It is cured by reacting with the humidity in the air.
  • Maintains its characteristics between -30°C and +90°C.
  • Offers water vapour permeability.
  • Features perfect adherence properties.


TECHNICAL VALUES

Colour
White, Grey
Density
1,40 g/cm³
Solid Content
~ % 90
Service Temperature
-30°C / +90°C
Floor Temperature
+5°C / +30°C
Walking on The Surface
16-24 hours at +23°C
Shore hardness
65 (7 days)
Tensile Strength DIN 53 504
> 5 N/mm² (7 days)
Breaking Strain DIN 53 504
% 800 (7 days)
Chemical resistance
Acidic and basic solutions
Water Vapour Permeability
Sd: 1,6 m
Crack Bridging
2 mm

NOTE: Technical data are given for environments with a temperature of +23°C and a relative humidity of 50%.




APPLICATION

SURFACE PREPARATION

  • Application surface shall be solid, free of any type of oil, grease, corrosion, paraffin, paint, bitumen residues and any loose parts shall be moved away.
  • The surfaces to be applied with primer shall be free from dust and shall not contain errors such as dents, breaks and cracks, etc.
  • Such uneven surfaces and corner edges shall be repaired with DOLTEK® repair mortars with a minimum radius of 4 cm before the application.
  • If SUTOP® PU-1B shall be applied on absorbent surfaces such as concrete, precast concrete etc., it shall be primed with SUTOP® PRIMEL PU; and if shall be applied on bright non-absorbent surfaces such as ceramic, granite, marble, metal etc., it shall be primed with SUTOP® PRIMEL PU (SILAN).
  • Wait at least for 3-4 hours to ensure that the primer has dried.
  • Primer shall be applied to the surface by a roll, brush or sprayer.

PREPARATION of the MORTAR

  • SUTOP® PU-1B that has been kept in room temperature for 24 hours is mixed with a mixer with a suitable mixer bit at 300-400 rpm until the mixture becomes homogeneous.
  • The mixture obtained shall be applied to the primed surfaces as one coat or two coats using a thin comb, trowel, roll brush with short bristles or with a suitable sprayer.
  • The layer shall protected against water rain, external factors and mechanical forces until it is dried.
  • While the waiting period between application of coats varies as per the ambient conditions, the period to start the second coat is usually 12 hours.
  • You shall consider that the waiting period may be reduced in hot weather and that it may be longer in cold weather.

1
SUTOP PU-1B Image 1

2
SUTOP PU-1B Image 2

3
SUTOP PU-1B Image 3

📊
CONSUMPTION

Standard Use:

SUTOP® PRIMEL PU 0,20 kg/m² / SUTOP® PU-1B 0,75 – 1,00 kg/m² (for a single coat)

Reinforced Use:

SUTOP® PRIMEL PU 0,20 kg/m² / SUTOP® PU-1B 0,85 – 1,25 kg/m² (for a single coat)

Note: The values provided in our table are the average consumption values. Additional consumption shall be determined by the user according to different surface properties.

📦
PACKAGING

25 kg circular lids canister
(delivered in pallets upon request.)

💾
STORING

1 Year Shelf Life*
* If stored in its original package without opening the package under dry, frost free conditions


RECOMMENDATION

  • Contains solvents, combustible.
  • Water vapour pressure from the negative side shall not be observed on the application surfaces.
  • After application, the surface shall be protected against water, rain, dew, snow, hail, etc. until it is dry.
  • It shall not be applied in enclosed areas due to long-lasting solvent odour, and the surface temperature shall be +5°C.
  • After the application, tools shall be cleaned with soapy water and thinner.
  • The package shall be kept at +15°C for at least 24 hours during application.
  • It should be considered that full mechanical and chemical strength shall be achieved in 7 days.
  • Storage conditions shall be considered while it is transported.
  • Work clothing, protective gloves and goggles conforming with the Occupational Health and Safety Rules shall be used during the application.
  • Do not inhale it directly.
  • Do not approach with open flames and do not smoke during application.
  • Avoid contact with eye and skin. In case of contact, wash with plenty of water and soap.
  • Consult a physician immediately in case of swallowing.
  • Do not use empty packages to store food and do not throw them in fire.
  • Food and drinks shall not be allowed in application areas.
  • Shall be stored away from the children.
  • Do not go beyond the application field and the rules.
  • For detailed information, please request the security data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.


CERTIFICATE OF CONFORMITY