FiNKOT®

Cement-Based High Performance Termal Insulation Board Plaster With Polymer Additives



APPLICATION FIELD

Used for coating of polystyrene and STONEWOOL plates.

+
REQUIREMENTS

  • It may be applied on XPS, EPS and STONEWOOL.
  • Provides a smooth surface.
  • It has polymer additives.


TECHNICAL VALUES

Adhesive Strength, N/mm²
≥ 0,1
Shininess
Matt; G3
Dry Film Thickness
> 400; E5
Grain Size, μm
< 1500; S3
Water Vapour Transmission Rate, g/(m².day)
15<V2≤150
Water Transmission Rate, kg/(m².hour0.5)
W2
Crack Bridging
A0
CO2 Permeability
C0
Resistance To Mould Growth
K2
TS EN 1062-1
G3 E5 S3 V2 W2 A0 C0 K2




APPLICATION

PREPARATION of the MORTAR

  • A proper amount of water shall be put inside the mixing container (6-6.75 l water/25 kg bag).
  • Powder material shall be added and stirred with a low speed hand mixer.
  • After resting for 5 minutes, the plaster shall be stirred until achieving a homogeneous mixture.
  • One coat of mortar with 3 mm of thickness shall be applied by steel trowel on the panel which had been fixed on the wall.
  • Reinforcement fiber mesh shall be placed by stretching it and without folding it, and the connection points of the mesh shall be overlapped. Net shall be applied with a steel trowel to ensure the contact of fresh mortar with the net.
  • Second coat (2 mm) of plaster shall be applied after applying the plaster.
  • A steel trowel is recommended to finish the surface. Sponge float may cause dusting of the surface.

1
Finkot Application Step 1

2
Finkot Application Step 2

3
Finkot Application Step 3

📊
CONSUMPTION

4,5 kg/m² (for 5 mm of thickness)

📦
PACKAGING

25 kg polyethylene-reinforced kraft paper bags
(delivered in pallets or as sling-bags upon request.)

💾
STORING

1 Year Shelf Life*
* If stored in its original package without opening the package under dry, frost free conditions (1 week after opening the package.)


RECOMMENDATION

  • No other materials (lime, cement, gypsum, etc.) shall be added to the prepared mortar.
  • Plaster shall not be used again by mixing with water or dry plaster if its application time has expired.
  • Surface shall be watered in specific intervals within 3 days after the application to ensure the strength of plaster depending on the weather conditions.
  • We recommend that the application shall be performed between +5°C and +35°C.
  • FINKOT® shall be protected against quick drying under windy weather conditions.
  • It shall not be applied on frozen surfaces.
  • Do not apply under direct sunlight.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the security data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.


CERTIFICATE OF CONFORMITY

TS 7847 / G3-E5-S3-V2-W2-A0-C0

Ministry of Public Works Pos. No: 04,481

TSE Logo

CE Logo

TCL Logo

×
Enlarged Image