GAZBETONFiX®

Cement-Based Aerated Concrete Masonry Mortar



APPLICATION FIELD

Used for masonry with aerated concrete.

+
REQUIREMENTS

  • Offers a good performance with its high adherence characteristic.
  • Provides convenient application thanks to its adequate application and incrustation time.


TECHNICAL VALUES

Dry Bulk Density of Hardened Mortar, kg/m³
1400 ± 200
Dry Bulk Density, g/cm³
Approx. 1,2
Processing Time, min.
≥ 120
Smoothing Time, min.
10 ± 5
Compressive Strength, N/mm²
≥ 5,0 (M 5)
Greatest grain size of the aggregate, mm
≤ 2
Capillary Water Absorption, kg/m²·min⁰·⁵
≤ 2,5
Water Vapour Permeability Coefficient (µ)
5/20
Reaction to Fire
A1




APPLICATION

GAZBETONFIX® shall be mixed by hand or preferably with power mixer (8-8.5 l water/25 kg bag).

While preparing the mortar:

  • Water shall be put to the plastic vessel first, then GAZBETONFIX® shall be added and mixed.
  • Stop for 5 minutes, and stir again to achieve a homogeneous mixture.

The mortar prepared shall be applied to the vertical and horizontal surfaces with a comb.

Ensure that joint thickness is at least 3 mm.

Aerated concrete block placed shall be seated by hammering from the top and side.

IMAGES

1

GAZBETONFIX Image 1

2

GAZBETONFIX Image 2

3

GAZBETONFIX Image 3

APPLICATION VIDEO

For more information, please watch our application video.

CONSUMPTION

2-3 kg/m²

(This is the consumption when mortar is applied with a thickness of 3 mm to a surface of 1 m²)

Consumption that shall be determined as per the wall area shall be calculated considering the brick dimensions.


PACKAGING

25 kg Paper Bag, (delivered in pallets or as sling-bags upon request.)

STORING

1 Year Shelf Life*

* If stored in its original package without opening the package under dry, frost free conditions

(1 week after opening the package.)


CERTIFICATE OF CONFORMITY

TS EN 998-2 / January 2017

T Type (Designed Ready-Mixed Fine Layer Mortar)

Ministry of Public Works Pos. No: 04.478

TSE Logo

CE Logo

TCL Logo


RECOMMENDATION

  • First line shall be put in level with cemented mortar.
  • No other materials (lime, cement, gypsum, etc.) shall be added to the prepared mortar.
  • We recommend that the application shall be performed between +5°C and +35°C. Curing period may be longer or shorter at other weather conditions.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly as it is a cement-based material. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the safety data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.

×