FUGAFiX® POOL

Cement-Based High Performance Joint Filler Developed for Pool Applications

23 Different Colour Options for a Thickness of 1-6 mm



APPLICATION FIELD

Used for filling of joints of coating materials on environments with high level of humidity such as pools, saunas, thermal springs, etc. and on open areas such as terraces, balconies, gardens, etc.

It may also be used for joint applications of coating materials such as ceramic, granite ceramic, natural rock, porcelain, marble, etc. in all areas thanks to its high performance and water repellent characteristics.

It may be used on floorings with floor heating system, floors exposed to high level of traffic, cold storage rooms, floors exposed to vibration, and ceramic modification applications.

+
REQUIREMENTS

  • Has an elastic structure.
  • Provides high performance on pool applications.
  • Used for applications of ceramics over ceramics.
  • Resistant against growth of mould and fungi.
  • Provides a smooth and bright surface.
  • Has a high wear resistance.
  • Highly water repellent.
  • Resistant to water and freezing.


TECHNICAL VALUES

Application Time, hours
< 2
Water Absorption, 30 minutes later, g (EN 12808-5)
≤ 2
Water Absorption, 240 minutes later, g (EN 12808-5)
≤ 5
Contraction, mm/m (EN 12808-4)
≤ 3
Bending Strength After Dry Storage, N/mm² (EN 12808-3)
≥ 2,5
Bending Strength After Freezing-Thawing Cycle, N/mm² (EN 12808-3)
≥ 2,5
Compressive Strength After Dry Storage, N/mm² (EN 12808-3)
≥ 15
Compressive Strength After Freezing-Thawing Cycle, N/mm² (EN 12808-3)
≥ 15
Wear Resistance, mm³ (EN 12808-2)
≤ 1000




APPLICATION

SURFACE PREPARATION

  • Scrape any dust, chipping, construction-cement waste that may be present inside the joint hole and clean with a brush before application.
  • Joint hole shall be dampened with water before application, if required.

PREPARATION of the MORTAR

  • Water shall be put to the mixing vessel first, then FUGAFIX® POOL shall be added (5.5-6.5 l water/20 kg bag) and it shall be stirred until the lumps are removed.
  • We recommend you to use a hand mixer at low speed for mixing. Wait for 5 minutes, and stir again to achieve a homogeneous mixture.
  • The mortar prepared shall be applied with a rubber ended scraper or a rubber trowel with a suitable thickness.
  • Approximately 25 minutes after the application, surface shall be cleaned with a damp sponge.
  • This period may be shorter for coating materials with heated surface or with high water absorption rate and for applications that are performed under improper conditions.
  • Fluctuation may occur on the joint surface when the wiping operation is performed before its due time or with an excessively dampened sponge. Sponge shall be cleaned frequently.
  • After ensuring that FUGAFIX® POOL is cured so that it shall not be drained from the joint gap, clean any residues on the surface with a dry cloth.
  • Application surface shall be dampened at least 1 day after the application.
  • When the surface cleaning operation is not performed adequately, the joint filler residues on the coating may be cleaned with a suitable cement stain remover (PRIMEL 300®) after 10 days.

1
FUGAFIX POOL Image 1

2
FUGAFIX POOL Image 2

3
FUGAFIX POOL Image 3

📊
CONSUMPTION

Consumption Amount (g/m²)*

Ceramic Size (cm) Joint Gap (mm) 1 mm 3 mm 4 mm 5 mm 6 mm
10×20 165 500 670 830 1000
15×15 150 440 590 740 880
15×20 130 390 520 650 780
20×20 110 330 440 550 660
20×25 100 300 400 500 600
20×30 95 280 370 470 560
33×33 70 200 270 340 400

* Coating material with a low water absorption rate at a thickness of 10 mm is taken as a reference.

📦
PACKAGING

5 kg polyethylene bags,
10 kg and 20 kg polyethylene-reinforced kraft paper bags,
(delivered in pallets or as sling-bags upon request.)

💾
STORING

6 Months Shelf Life*
* If stored in its original package without opening the package under dry, frost free conditions
(1 week after opening the package.)


RECOMMENDATION

  • No other materials (lime, cement, gypsum, etc.) shall be added to the prepared mortar.
  • Plaster shall not be used again by mixing with water or dry plaster if its application time has expired.
  • You shall wait at least 24 hours for joint application after fixing operation.
  • We recommend that the application shall be performed between +5°C and +35°C.
  • It shall not be applied on frozen surfaces.
  • A suitable cement cleaning agent shall be used for cleaning of the contaminated joints.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • Wash your hands and application tools with plenty of water after application.
  • For detailed information, please request the security data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.


CERTIFICATE OF CONFORMITY

TS EN 13888 / March 2010

Complies with CG2WA Class.

CG2WA: Advanced Cement-based Joint Filler Material With Additional Qualities of Reduced Water Absorption and High Wear Resistance

Ministry of Public Works Pos. No: 04.013/2

TSE Logo

CE Logo

TCL Logo

×
Enlarged Image