FUGAFiX GENiŞ ®

Cement-Based Joint Filler

(2 Different Colour Options for a Thickness of 6-15 mm)



APPLICATION FIELD

Used for filling of 6-15 mm joints of ceramic and tile coating materials on horizontal and vertical floors in interior and exterior areas in dry and medium wet environments.

+
REQUIREMENTS

  • Applied easily.
  • It has a smooth appearance.
  • Used conveniently on interior and exterior surfaces both vertically and horizontally.


TECHNICAL VALUES

Application Time, hours
< 1,5
Water Absorption, 30 minutes later, g (EN 12808-5)
≤ 5
Water Absorption, 240 minutes later, g (EN 12808-5)
≤ 10
Contraction, mm/m (EN 12808-4)
≤ 3
Bending Strength After Dry Storage, N/mm² (EN 12808-3)
≥ 2,5
Bending Strength After Freezing-Thawing Cycle, N/mm² (EN 12808-3)
≥ 2,5
Compressive Strength After Dry Storage, N/mm² (EN 12808-3)
≥ 15
Compressive Strength After Freezing-Thawing Cycle, N/mm² (EN 12808-3)
≥ 15
Wear Resistance, mm³ (EN 12808-2)
≤ 2000




APPLICATION

SURFACE PREPARATION

  • Scrape any dust, chipping, construction-cement waste that may be present inside the joint hole and clean with a brush before application. Joint hole shall be dampened with water before application, if required.

PREPARATION of the MORTAR

  • Water shall be put to the mixing vessel first, then FUGAFIX® GENİŞ shall be added (4.0-4.5 l water/20 kg bag) and it shall be stirred until the lumps are removed.
  • Wait for 5 minutes, and stir again to achieve a homogeneous mixture.
  • The mortar prepared shall be applied with a rubber ended scraper with a suitable thickness. Approximately 30 minutes after the application, surface shall be cleaned with a damp sponge. This period may be shorter for coating materials with heated surface or with high water absorption rate and for applications that are performed under improper conditions.
  • Fluctuation may occur on the joint surface when the wiping operation is performed before its due time or with an excessively dampened sponge. Sponge shall be cleaned frequently. After ensuring that FUGAFIX® is cured so that it shall not be drained from the joint gap, clean any residues on the surface with a dry cloth.
  • Application surface shall be dampened at least 1 day after the application.
  • When the surface cleaning operation is not performed adequately, the joint filler residues on the coating may be cleaned with a suitable cement stain remover (PRIMEL 300®) after 10 days.

1
FUGAFIX GENİŞ Image 1

2
FUGAFIX GENİŞ Image 2

3
FUGAFIX GENİŞ Image 3


APPLICATION VIDEO

For more information, please watch our application video.

📊
CONSUMPTION

Consumption Amount (g/m²)*

Ceramic Size (cm) Joint Gap (mm) 6 mm (g/m²) 10 mm (g/m²) 15 mm (g/m²)
10×20 1000 1730 2590
15×15 920 1530 2300
15×20 800 1340 2000
20×20 690 1150 1730
20×25 1000 1650 2490
20×30 920 1530 2300
33×33 670 1110 1680

📦
PACKAGING

It is shipped in 20 kg kraft bags, on pallets.

💾
STORING

Storage period: It is recommended to be consumed in 6 months from the date of production if stored in its original package without opening the package under dry, frost free conditions and is stacked as maximum 8 bags, and in 1 week after opening the package.

Packages shall be tightly closed when it is not used.


RECOMMENDATION

  • No other materials (lime, cement, gypsum, etc.) shall be added to the prepared mortar.
  • Plaster shall not be used again by mixing with water or dry plaster if its application time has expired.
  • You shall wait at least 24 hours for joint application after fixing operation.
  • We recommend that the application shall be performed between +5°C and +35°C.
  • It shall not be applied on frozen surfaces.
  • Do not apply under direct sunlight.
  • PRIMEL 300® shall be used for cleaning of the contaminated joints.
  • To prevent damage to the coloured joint fillings, do not use strong chemical cleaning agents such as lime remover, hydrochloric acid, etc.
  • Do not go beyond the application field and the rules.
  • Do not inhale it directly. Wash your eyes with plenty of water in case of contact with eyes, seek medical attention if required.
  • For detailed information, please request the security data sheet.
  • Contact us for your technical questions and for your questions about all other application conditions.


CERTIFICATE OF CONFORMITY

TS EN 13888 / March 2010

Complies with CG1 Class.

CG1: Normal Cement-Based Joint Filler

TSE Logo

CE Logo

TCL Logo

×
Enlarged Image